What is required for every subdivision where a tentative and final map is required pursuant to Section 66428 of the Government Code?
A preliminary soil report
What should the soil investigation recommend in cases of critically expansive soils or other soil problems?
Corrective action likely to prevent structural damage to each dwelling proposed to be constructed
How is the upward pressure of water considered in design calculations?
As the full hydrostatic pressure applied over the entire area
What action is required if the preliminary soil report indicates the presence of critically expansive soils or other soil problems?
A soil investigation of each lot in the subdivision
Under what circumstances can the preliminary soil report be waived?
If the building department determines that no preliminary analysis is necessary due to knowledge of the soil qualities
What is the role of the building department regarding soil investigations in areas with soil problems?
To approve the soil investigation if it determines that the recommended action is likely to prevent structural damage
Who is responsible for conducting geotechnical investigations involving in-situ testing, laboratory testing, or engineering calculations?
A registered design professional
Who is responsible for preparing the soil investigation for each lot if critically expansive soils are found?
A civil engineer who is registered in the state
What is the maximum depth below grade for foundation walls that can be designed for active pressure when supported by flexible diaphragms at the top?
8 feet
What factor must be considered when designing basement floors and slabs on ground?
Uplift loads
What standard is used for the definition and classification of soil materials in Table 1610A.1?
ASTM D2487
Under what conditions can retaining walls be designed for active pressure?
When free to move and rotate at the top
Why are organic clays and silty clays (OH) unsuitable as backfill material?
They have unpredictable and potentially unstable properties
How does the presence of expansive soils affect lateral pressure on foundation walls?
It increases lateral pressure
How should the upward pressure of water be calculated for design purposes?
As the full hydrostatic pressure
What is the active pressure design lateral soil load for well-graded, clean sands according to Table 1610A.1?
30 pounds per square foot per foot of depth
What type of pressure should foundation walls with restricted horizontal movement at the top be designed for?
At-rest pressure
How is hydrostatic load measured for design purposes?
From the underside of the element being evaluated
How are the specifications for controlled low-strength material (CLSM) determined?
Through a geotechnical investigation
What potential geologic and seismic hazards must be evaluated for structures assigned to Seismic Design Categories C through F?
Slope instability, liquefaction, and total and differential settlement
What recommendations must be included in the geotechnical report regarding foundation design criteria?
Bearing capacity, mitigation of expansive soils and liquefaction, and effects of adjacent loads
What is the purpose of specifying the number and frequency of field tests for compacted fill material?
To determine compliance with minimum acceptable in-place dry density requirements
What information is not typically required in the geotechnical report submitted to the building official?
Construction timeline and cost estimates
Why might a building official require a geotechnical investigation for alternate setbacks and clearances?
To demonstrate that the intent of Section 1808.7 would be satisfied
What is the minimum acceptable in-place dry density of compacted fill material expressed as?
A percentage of the maximum dry density determined by specified test methods
What aspect of compacted fill material must be specified according to the geotechnical investigation requirements?
The maximum allowable thickness of each lift
When must a written report of geotechnical investigations be submitted to the building official?
At the time of permit application
How is the compressive strength or bearing capacity of controlled low-strength material (CLSM) determined?
Through laboratory or field test methods
How deep can foundation walls extend below grade and still be permitted to be designed for active pressure when laterally supported at the top by flexible diaphragms?
Not more than 8 feet (2438 mm)
What factor must be added to the lateral soil load when designing retaining walls?
Lateral pressure from surcharge loads
According to the document, how should soil materials be classified and defined?
They shall be in accordance with ASTM D2487
What condition allows retaining walls to be designed for active pressure?
When free to move and rotate at the top
When must foundation walls support the full hydrostatic pressure of undrained backfill?
When a drainage system is not installed
What type of soil, according to Table 1610.1, has the highest active pressure design lateral soil load?
Clayey sands, poorly graded sand-clay mixes
When measuring hydrostatic load for upward loads on horizontal elements, from where should the measurement be taken?
From the underside of the element being evaluated
How does the presence of expansive soils at a site affect lateral pressure in wall design?
Lateral pressure shall be increased
What type of pressure should foundation walls and other walls with restricted horizontal movement at the top be designed for?
At-rest pressure
How should basement floors, slabs on ground, and similar horizontal elements below grade be designed in relation to uplift loads?
They should be designed to resist uplift loads where applicable
What is the minimum in-place dry density requirement for compacted fill material that does not require an approved report?
90 percent of the maximum dry density at optimum moisture content
What must be used to cover the top of the foundation drain?
An approved filter membrane material
What is the maximum allowable increase in design flood elevation when flood hazard area encroachment is proposed in areas without designated floodways?
1 foot (305 mm)
What is the maximum depth of compacted fill material before it requires compliance with an approved geotechnical report?
12 inches (305 mm) or less
How should the floor base and foundation perimeter drain discharge be accomplished?
By gravity or mechanical means into an approved drainage system
What material is specified for the foundation drain around the perimeter of a foundation?
Gravel or crushed stone
Under what soil conditions is a dedicated drainage system not required?
Well-drained gravel or sand/gravel mixture soils
What is the minimum distance the foundation drain must extend beyond the outside edge of the footing?
Not less than 12 inches (305 mm)
Who is responsible for administering and enforcing the provisions of Section 1803.1.1?
A city, county, city and county, or other enforcement agency.
What condition must be met before a building permit is issued for dwellings in areas prone to earthquakes?
The approved recommended action to prevent structural damage must be incorporated in the construction of each dwelling.
How can a city, county, or city and county enact an alternative procedure to the one specified in Section 1803.1.1?
By enacting an ordinance prescribing a procedure that is equal to or more restrictive than the specified procedure.
What action is required when subsurface explorations indicate variations in the structure of rock on which foundations are to be constructed?
A sufficient number of borings shall be conducted.
What is the purpose of the ordinance requiring approved recommended action to be incorporated into dwelling construction?
To prevent structural damage to each dwelling to be constructed.
When is a subsurface soil investigation required to determine the ground-water table location?
When the existing ground-water table is above or within 5 feet below the elevation of the lowest floor level located below the finished ground level adjacent to the foundation.
What are the four criteria used to determine if soil is considered expansive?
Plasticity index of 15 or greater, more than 10% of soil particles pass a No. 200 sieve, more than 10% of soil particles are less than 5 micrometers in size, and expansion index greater than 20.
What are the required elements of a geotechnical investigation for deep foundations?
Recommended deep foundation types and capacities, spacing, driving criteria, installation procedures, field inspection and reporting procedures, load test requirements, material suitability, bearing stratum designation, and group action reductions.
What must be included in the geotechnical investigation for compacted fill material?
Specifications for site preparation and for material to be used as compacted fill.
What are the potential geologic and seismic hazards that must be evaluated for structures assigned to Seismic Design Category C through F?
Slope instability, liquefaction, total and differential settlement, and surface displacement due to faulting or seismically induced lateral spreading or lateral flow.
What are some mitigation measures that can be implemented for structures in Seismic Design Categories D through F?
Selection of appropriate foundation type and depths, appropriate structural systems, ground stabilization, or a combination of these measures.
What is required when shallow foundations will bear on compacted fill material more than 12 inches in depth?
A geotechnical investigation must be conducted.
How can peak ground acceleration be determined for structures in Seismic Design Categories D through F?
Through a site-specific study in accordance with Chapter 21 of ASCE 7 or in accordance with Section 11.8.3 of ASCE 7.
What is required when excavation will reduce support from any foundation?
A registered design professional must prepare an assessment of the structure.
How must support be provided for existing foundations during nearby excavations?
By underpinning, bracing, excavation retention systems, or other means acceptable to the building official.
What are some potential consequences of liquefaction and soil strength loss that must be assessed?
Total and differential settlement, lateral soil movement, lateral soil loads on foundations, and reduction in foundation soil-bearing capacity.
What exception applies to geohazard report requirements for certain healthcare facilities?
One-story, wood-frame and light-steel-frame buildings of Type V skilled nursing or intermediate care facilities construction and 4,000 square feet or less in floor area
What is the primary purpose of a geohazard report in construction projects?
To identify geologic and seismic conditions that may require project mitigations
What aspect of regional geology must be evaluated in a geohazard report?
Known active and potentially active faults
What condition must be met for grading and fill to be approved in floodways?
It must be demonstrated that the proposed grading or fill will not result in any increase in flood levels
How does the California Geological Survey (CGS) Special Publication 42 relate to geohazard reports?
It should be considered for project sites proposed within an Alquist-Priolo Earthquake Fault Zone
Who is responsible for preparing geohazard reports for construction projects?
A California-certified engineering geologist in consultation with a California-registered geotechnical engineer
How should fill be placed in flood hazard areas to minimize risks?
Placed, compacted and sloped to minimize shifting, slumping and erosion during flood water rise and fall
What information regarding ground motion must be included in the geohazard report?
Ground-motion parameters as required by Section 1613 and ASCE 7