How should soil materials be classified according to Section 1803A.5.1?
In accordance with ASTM D2487
When is a subsurface soil investigation required to determine the existing ground-water table?
When the lowest floor level is located below the finished ground level adjacent to the foundation
What is the minimum number of borings required for any one building during a geotechnical investigation?
Two
What additional evaluation is required for structures assigned to Seismic Design Categories C through F?
Evaluation of potential geological and seismic hazards
Who is responsible for the classification and investigation of soils according to Section 1803A.1?
A California registered geotechnical engineer
What is one criterion for soil to be considered expansive according to Section 1803A.5.3?
Plasticity index (PI) of 15 or greater
What is the primary scope of application for Chapter 18A of the California Building Code?
Building and foundation systems
How many of the specified criteria must be met for soil to be considered expansive?
All four criteria
What are the three main components of the assessment of potential consequences of liquefaction and soil strength loss?
Estimation of total and differential settlement, lateral soil movement, and lateral soil loads on foundations
How should walls or portions thereof that retain earth and enclose interior spaces and floors below grade be treated?
They should be waterproofed and dampproofed
What is the purpose of a foundation drain in a story above grade plane with a basement?
To manage groundwater when the finished ground level is below the basement floor elevation for 25 percent or more of the perimeter
What must be included in the geotechnical report regarding ground water conditions?
Elevation of the water table if encountered and historic high ground water elevations
When is a geohazard report not required for proposed construction?
For one-story wood frame and light steel frame buildings of Type II or Type V construction and 4,000 square feet or less in floor area
Why is underpinning sometimes necessary during excavation near foundations?
To protect the foundation against detrimental lateral or vertical movement
How must the ground immediately adjacent to the foundation be sloped for proper drainage?
Away from the building at a slope of not less than one unit vertical in 20 units horizontal (5-percent slope) for a minimum distance of 10 feet
What is the minimum dry density requirement for compacted fill material 12 inches or less in depth?
90 percent of the maximum dry density at optimum moisture content
What is the minimum plasticity index (PI) for soil to be considered expansive?
15 or greater
When is a geotechnical investigation not required according to the exceptions mentioned in the California Building Code Chapter 18?
For one-story wood frame and light-steel frame buildings of Type II or Type V construction and 4,000 square feet or less in floor area
What potential geological and seismic hazards must be evaluated for structures assigned to Seismic Design Category C through F?
Slope instability, liquefaction, total and differential settlement, and surface displacement
How many criteria must be met for soil to be considered expansive?
All four criteria
What is the minimum number of borings required for any one building according to the California Building Code Chapter 18?
Two borings
What is the minimum depth requirement for ground-water table investigation in relation to the lowest floor level?
Within 5 feet below the elevation of the lowest floor level
Who is responsible for determining the scope of the geotechnical investigation?
A registered design professional
What additional requirement is specified for structures assigned to Seismic Design Categories D through F regarding foundation walls?
Determination of dynamic seismic lateral earth pressures on foundation walls
When is the wave equation method of analysis required for estimating driveability of deep foundation elements?
For allowable loads above 160 tons (1423 kN)
What is the maximum allowable shaft resistance for an uncased cast-in-place deep foundation element without additional verification?
One-sixth of the bearing value of the soil material at minimum depth, up to 500 psf (24 kPa)
What ASTM standard is specified for load testing of deep foundation elements?
ASTM D1143
What is the minimum ratio of steel yield strength (Fy) to specified compressive strength (f'c) required for increased allowable compressive stress in cased mandrel-driven cast-in-place elements?
6
What is the minimum factor of safety required when determining the uplift capacity of a single deep foundation element by an approved method of analysis?
Three
What is the maximum allowable compressive stress for cast-in-place concrete with a permanent casing in deep foundation elements?
0.4 f'c
What is the maximum nominal diameter allowed for deep foundation elements with increased allowable compressive stress?
16 inches (406 mm)
How is the effectiveness of protective measures for deep foundation elements established?
By satisfactory service records or other evidence
What is the purpose of the stability check for isolated spread footings supporting freestanding cantilever walls?
To evaluate the possibility of overturning
How is the total resistance to lateral loads determined when using presumptive values?
By combining the values derived from the lateral bearing pressure and the lateral sliding resistance
What is the minimum safety factor required for retaining walls to resist sliding and overturning?
1.5
What is the maximum increase allowed for lateral bearing pressures specified in Table 1806A.1?
15 times the tabular value
What type of soil should not be assumed to have a presumptive load-bearing capacity without supporting data?
Mud, organic silt, organic clay, peat, or unprepared fill
How should wood poles used in embedded posts and poles be treated?
In accordance with AWPA U1 for sawn timber posts and AWPA C4 for round timber posts
What is the primary goal when designing foundations in areas with expansive soils?
To minimize differential settlement
When designing retaining walls supporting more than 6 feet of backfill height in Seismic Design Category D, E, or F, what additional factor must be incorporated?
Additional seismic lateral earth pressure
For structures assigned to Seismic Design Category C, D, E, or F, how must the ends of hoops, spirals, and ties in concrete deep foundation elements be terminated?
With seismic hooks turned into the confined concrete core
What is the maximum allowable compressive overload of deep foundation elements to resist the effects of mislocation?
10 percent of the allowable design loads
What is the classification of deep foundation elements standing unbraced in air, water, or fluid soils?
Columns
How should the foundation or superstructure be designed to account for potential mislocation of deep foundation elements?
To resist the effects of mislocation by not less than 3 inches.
What is the minimum number of deep foundation elements connected by a rigid cap to be considered braced?
Three elements
Why must the settlement of a single deep foundation element or group be estimated?
To ensure it causes neither harmful distortion of nor instability in the structure.
What additional requirement applies to deep foundation elements on Site Class E or F sites in Seismic Design Categories D through F?
They must be designed to withstand maximum imposed curvatures from earthquake ground motions and structure response.
How is lateral support for deep foundation elements determined in soil other than fluid soils?
Any soil other than fluid soil is deemed to afford sufficient lateral support to prevent buckling.
What is the minimum height that the top of any exterior foundation should extend above the elevation of the street gutter at the point of discharge?
12 inches (305 mm) plus 2 percent
What is the required setback for pools regulated by this code from slopes?
One-half the building footing setback distance required by this section
What combinations of loads must be considered when designing foundations?
The most unfavorable effects due to the combinations of loads specified in Section 1605.2 or 1605.3
What is a primary goal in foundation design regarding differential settlement?
To minimize differential settlement
How should foundations on or within the active zone of expansive soils be designed?
To resist differential volume changes and to prevent structural damage to the supported structure
How should foundations be designed to address the allowable bearing capacity of the soil?
Foundations shall be designed so that the allowable bearing capacity of the soil is not exceeded.
What is required when fill or other surcharge loads are placed adjacent to a building or structure?
The building or structure must be capable of withstanding the additional loads caused by the fill or surcharge
When are foundations required to be designed in accordance with the provisions of Section 1808.6?
When foundations are in areas with expansive soils
What is the purpose of a filter membrane material in foundation drainage systems?
To protect the top of joints or perforations in drain pipes
How should the total resistance to lateral loads be determined when using presumptive values?
By combining the values derived from lateral bearing pressure and lateral sliding resistance
What condition necessitates the use of waterproofing instead of dampproofing for walls and floors?
The presence of hydrostatic pressure
What is the minimum thickness required for a floor base course in basements according to the given specifications?
4 inches (102 mm)
How should joints in dampproofing membranes be treated during installation?
Joints should be lapped and sealed according to the manufacturer's installation instructions.
What is the primary purpose of the floor base course in basement construction?
To provide drainage and reduce hydrostatic pressure on the floor
When can the presumptive load-bearing values provided in the code be increased by one-third?
When used with alternative basic load combinations that include wind or earthquake loads
How should concrete or masonry walls be prepared prior to the application of waterproofing materials?
Holes and recesses from form ties should be sealed with a bituminous material or other approved methods
Under what condition must walls or portions thereof that retain earth and enclose interior spaces and floors below grade be waterproofed and dampproofed?
When the omission is detrimental to the building or occupancy
What is the minimum slope required for the ground immediately adjacent to the foundation?
One unit vertical in 20 units horizontal (5-percent slope) for a minimum distance of 10 feet
What must be included in the geotechnical report regarding ground motion parameters?
The report must utilize the Next Generation Attenuation West (NGA-West) relations used for the USGS seismic hazards maps for Western United States
How should peak ground acceleration be determined for liquefaction and soil strength loss evaluation?
Based on a site-specific study, in accordance with ASCE 7, or Section 11.8.3 of ASCE 7
For what type of construction are geohazard reports not required?
One-story wood frame and light steel frame buildings of Type II or Type V construction and 4,000 square feet or less in floor area
What is required in the geotechnical investigation for structures assigned to Seismic Design Category D, E, or F when supporting more than 6 feet of backfill height?
The determination of dynamic seismic lateral earth pressures on foundation walls and retaining walls
What is the minimum in-place dry density required for compacted fill material 12 inches or less in depth?
90 percent of the maximum dry density at optimum moisture content
When is underpinning required during excavation near foundations?
When excavation reduces vertical or lateral support for any foundation or adjacent foundation
Under what conditions are shallow foundations not required to be protected from frost?
When constructed on solid rock
How long must concrete foundations be protected from freezing after depositing?
For a period of not less than 5 days
How should pipes crossing under footings be accommodated?
The footings shall be specially designed.
How should concrete be placed to ensure the exclusion of foreign matter and secure a full-size foundation?
Concrete shall be placed in such a manner as to ensure the exclusion of any foreign matter and to secure a full-size foundation.
How should deep foundation elements left in place where a structure has been demolished be evaluated for use in new construction?
They should be load tested or redriven to verify their capacities.
What is the minimum depth of footings below the undisturbed ground surface?
12 inches (305 mm)
What is the maximum permitted slope for the bottom surface of footings?
One unit vertical in 10 units horizontal (10 percent slope)
What is required for individual spread footings founded on soil defined as Site Class E or F in structures assigned to Seismic Design Category D, E, or F?
They shall be interconnected by ties.
What is the minimum specified compressive strength (f'c) required for concrete foundations in structures assigned to Seismic Design Category D, E, or F?
3000 psi
What is the minimum concrete cover required for cast-in-place deep foundation elements not enclosed by a steel pipe, tube, or permanent casing?