How does a smaller pixel size affect image resolution in digital radiography?
It improves resolution
What is the role of europium in CR phosphor screens?
It acts as an impurity to enhance luminescence
What is the smallest complete sample of an image called in digital radiography?
Pixel
What material is commonly used in the phosphor layer of CR plates?
Europium-activated barium fluorohalide
What are the three main stages in the principle of photostimulable phosphor (PSP) operation?
Excitation, storage, and emission
How does increasing the concentration of impurity ions in CR phosphor screens affect luminescence?
It increases the intensity of luminescence
What does the term "bit depth" refer to in digital radiography?
The number of shades used to define each pixel
What is the primary function of the anti-halo layer in a CR plate?
It prevents the laser from passing through
Why is lead foil included in the back panel of CR cassettes?
To protect the plate from backscatter
How does Computed Radiography (CR) differ from conventional radiography in terms of image receptors?
CR uses a photostimulable plate instead of film
What is the primary advantage of CR systems over conventional film in terms of exposure latitude?
CR systems have a much greater latitude than screen/film, allowing for salvaging of over- and under-exposed images.
What does QDE stand for in the context of CR system efficiency?
Quantum Detection Efficiency
How long can a latent image remain stored on a CR plate before significant fading occurs?
The latent image will remain stored for 24 hours, with 25% of stored energy fading within 8 hours.
What is the function of DICOM in medical imaging?
DICOM is a standard for handling, storing, printing, and transmitting information in medical imaging.
What is the primary purpose of a Picture Archiving and Communication System (PACS)?
To replace conventional analogue film and paper clinical request forms with a computerized electronic network for digital images and patient information.
What defines the lifespan of a CR plate?
Plate life is defined by physical wear, not by erasure cycles.
How does Digital Radiography (DR) differ from Computed Radiography (CR) in terms of image availability?
DR images are available in less than 15 seconds, while CR requires more processing time.
What process occurs when a CR plate is exposed to high-frequency light from a helium laser?
Electrons in F-centers are liberated and cause luminescence at readout.
How does DICOM facilitate the integration of medical imaging devices?
It enables integration of devices from multiple manufacturers into a PACS
Where has DICOM been widely adopted?
Hospitals
What types of devices can be integrated using DICOM?
Scanners, servers, workstations, printers, and network hardware
What are the primary functions of DICOM in medical imaging?
Handling, storing, printing, and transmitting information
What two main components does DICOM include?
A file format definition and a network communications protocol
What do DICOM conformance statements provide?
They clearly state the DICOM classes supported by different devices
What does PACS stand for in the context of DICOM?
Picture archiving and communication system
What does DICOM stand for in the context of medical imaging?