Join 75,000+ students acing their exams with Studygenie
Unlimited practice
Flashcards, multiple choice and written questions, as many as you want.
Study sets in seconds
Turn your notes and files into a set with AI.
See your progress
Always know what you've learned and what's left.
Questions in this set (61)
What is the purpose of the incident base in a high-rise fire operation?
To serve as a reporting and level II staging point where personnel and equipment are not at risk
What does an "apartment stretch" in high-rise firefighting refer to?
Clear or light smoke conditions in the hallway of the fire floor, allowing firefighters to deploy the hose line uncharged
Where should staging be established in a high-rise fire incident?
In a non-IDLH environment, ideally two floors below the fire floor
What is the role of the cabinet firefighter in high-rise operations?
To be stationed at the standpipe connection on the floor below the fire
What action should be taken with hose bundles when setting up the initial line?
Lay all hose bundles in the hallway with male side facing towards the stairwell
How many high-rise hose packs should crews bring for the initial line setup?
A minimum of three high-rise hose packs
Where should RIT crews be staged in a high-rise fire incident?
One floor below the fire floor
Why is getting the initial line into service a priority in high-rise firefighting?
It takes precedence over setting up a second or back-up line
What is the primary responsibility of the cabinet firefighter in the initial setup?
Preparing the standpipe connection with gate valve, pressure gauge, and 45-degree elbow
How is the extra hose managed in the stairwell stretch procedure?
It is pulled down the hallway of the floor below the fire
When must the Incident Commander contact the on-call investigator?
When a civilian or firefighter has been injured or killed in a fire or explosion incident
What is the Incident Commander's responsibility regarding scene security in relation to fire investigation?
Provide scene security in anticipation of the arrival of the fire investigator
When is the Incident Commander required to document findings in the narrative for a wildland or dumpster fire?
When the fire was intentionally set and suspect information is available, unless damage was less than $2,000 and did not spread to a building or structure
What action should the Incident Commander take if a fire's cause is believed to be intentional?
Contact the on-call investigator
Where is the first hose pack positioned during the apartment stretch procedure?
At the door to the fire floor (drop point #2)
What action does the officer take during the second line deployment?
Goes to the fire floor for reconnaissance and assesses the progress of the initial attack line crew
What is the secondary VHF channel option for radio traffic?
VFire21
How should radio traffic be handled when operating across both 800MHz and VHF systems?
Move all radio traffic to VHF channels
What are the primary Air-to-Ground channels for federally and state contracted aircraft?
A/G 35 or A/G 10
Where should District resources maintain their radio communications?
On the appropriate WMFR TAC or SIMPLEX channel
What is the recommended approach for setting up the incident communications plan?
Use the pre-programmed initial attack groups in the BK radios
What determines the choice between VRedSW and VRedNW channels?
The location of the incident relative to I-70
Why is patching 800MHz and VHF radio traffic through Jeffcom discouraged?
To avoid potential communication issues and streamline radio traffic
What is the primary VHF channel for radio traffic south of I-70?
VRedSW
For what reason should gas-powered fans not be used during a flammable vapor incident?
They are considered an ignition source
How should district employees attempt to control the flow of a flammable vapor?
Through valve control upstream or remote from the leak
At what oxygen levels is the use of PPE and breathing apparatus required?
Below 19.5% or greater than 23.0%
What advice should be given to homeowners after addressing a gas odor complaint?
Seek professional appliance advice or call 911 if the odor returns
What action should be taken if an intrusion alarm is activated along with a fire alarm?
The responding unit shall stage until law enforcement units can investigate
What is the vapor density of natural gas?
0.6
What is the Lower Explosive Limit (LEL) for propane?
3.8% - UEL is 17%
What LEL reading indicates that an area can be considered stable after a gas leak?
Below 10%
How frequently should monitoring be repeated for unknown flammable vapor sources?
Every 15 to 20 minutes
In what situation should personnel force entry into a secured structure during a fire alarm investigation?
When there are obvious signs of smoke, fire, sprinkler activation, or hazardous conditions
What is the primary characteristic of mobile attack in wildfire suppression?
Suppressing fire while using apparatus with pump and roll capabilities
What is the primary function of the tactical tender in wildfire suppression?
To hold 2,000 gallons of water and provide mobile water supply operations
When is the use of fire as a tactic recommended according to WMFR?
When well-coordinated, within the objectives of the IAP, and by a qualified individual
What is the expectation for mop-up operations on in-District fires?
100% mop up depending on size, location, and visibility of fire
What is the purpose of back firing in wildfire suppression?
To consume the path of the fire, change its direction, or slow its spread
What are the four structure triage categories according to the IRPG?
Defensible Prep and Hold, Defensible Standalone, Non-Defensible Prep and Leave, Non-Defensible Rescue Drive-By
How is progressive attack defined in wildfire suppression?
The extension of the black wildland progressive hose packs
How is the "bump and run" tactic implemented in wildfire suppression?
Resources move ahead of the fire front extinguishing spot fires and defending structures
How should the Incident Commander report applicable fields under the Fire tab on the Basic NFIRS Incident Report when a fire investigator is assigned?
The Incident Commander should report applicable fields as "Under Investigation".
What information must be included in the incident report narrative regarding Fire Watch personnel?
The name, address, phone number, and date of birth of the person/persons responsible for the Fire Watch.
What is the primary responsibility of the Incident Commander regarding scene preservation in a fire investigation?
The Incident Commander is responsible for scene and evidence preservation, victim and witness statement collection, and documentation.
What action should the company officer take if the Life Safety Division will not receive an email notification about a Fire Watch for an extended period?
The company officer should contact the on-duty Investigator.
Who is responsible for establishing a Fire Watch when required?
The building owner/occupant is responsible for establishing a Fire Watch.
When is a Fire Watch required in a building with both fire detection and protection systems?
A Fire Watch is required when both systems are out of service and a life safety hazard exists.
Who is responsible for completing all civilian and firefighter casualty reports in a fire incident?
The Incident Commander is responsible for completing all civilian and firefighter casualty reports.
Under what circumstances may fire personnel force entry into a secured structure during a fire alarm investigation?
When there are obvious signs of smoke, fire, sprinkler activation, or hazardous conditions such as the smell of gas.
What does LCES stand for in the context of wildland firefighting?
Lookouts, communications, escape routes, and safety zones
When must water from hoselines be used in a direct attack on a wildland fire?
When flame lengths are greater than four feet
What should District employees avoid doing when encountering an escaping flammable vapor from a source line?
Attempting to clamp or plug the escaping vapor
What action must the incident commander take if a call has a scene time greater than 60 minutes?
Document contact information for all parties on scene in the report
How is a parallel attack defined in wildland firefighting?
Creating a fire line parallel to the main fire front
How many handlines are required for Excel employees mitigating a source in a trench for commercial feeder lines?
2 handlines
Why should a flammable vapor fire not be extinguished unless the source can be controlled?
To prevent uncontrolled vapor accumulation and potential explosion
What is the primary advantage of a direct attack in wildland firefighting?
It reduces fire growth
When should District employees enter a trench with escaping flammable vapor?
When there is a fire/explosion and a rescue is needed
What is the first step in the "Anchor, flank, and pinch" wildland fire attack strategy?
Securing an anchor point
What is the LEL/UEL of propane?
Propane is heavier than air with an LEL of 2.1% and a UEL of 9.5%